The corporate upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will keep on to serve outdated and new clients from home and abroad whole-heatedly for Vet Infusion Pump, Icu Syringe Pump, Insulin Pump Infusion Sites, Welcome buddies from all over the earth come to visit, tutorial and negotiate.
China Factory for Cassette Iv Pump - ZNB-XAII Infusion Pump – KellyMed Detail:

FAQ

Q: Is the pump open system?

A: Yes, Universal IV set can be used with our Infusion Pump after calibration.

Q: Does the pump compatible with Micro IV Set (1 ml=60 drops)?

A: Yes, all of our pumps are compatible with IV Set of 15/20/60 dorps.

Q: Is it a peristaltic pumping mechanism?

A: Yes, curvilinear peristaltic.

Q: What is the difference between PURGE and BOLUS function?

A: Purge used to remove air in line before infusion. Bolus can be administered for infusion therapy during infusion. Both purge and bolus rate are programmable.

 

Specifications

Model ZNB-XAII
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 0.1 ml/h increments)

Purge when pump stops, bolus when pump starts

Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-20000 ml (in 0.1 ml increments)
Infusion Mode ml/h, drop/min, time-based, body weight, nutrition
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby

Additional Features Real-time infused volume, automatic power switching, mute key,

purge, bolus, system memory, history log, key locker, drug library,

rotary knob, change flow rate without stopping the pump

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Air-in-line Detection Ultrasonic detector
Wireless management Optional
Drop Sensor Optional
Vehicle Power (Ambulance) 12±1.2 V
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 25 ml/h
Working Temperature 10-30℃
Relative Humidity 30-75%
Atmospheric Pressure 860-1060 hpa
Size 130*145*228 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF

Product detail pictures:

China Factory for Cassette Iv Pump - ZNB-XAII Infusion Pump – KellyMed detail pictures


Related Product Guide:

We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for China Factory for Cassette Iv Pump - ZNB-XAII Infusion Pump – KellyMed , The product will supply to all over the world, such as: Uruguay, Estonia, Chicago, Facing fierce global market competition, we have launched the brand building strategy and updated the spirit of "human-oriented and faithful service", with an aim to gain global recognition and sustainable development.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Natalie from Jakarta - 2018.09.21 11:44
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Kevin Ellyson from Kenya - 2018.06.30 17:29
    Write your message here and send it to us