Europe style for Excelsior Syringe Pump - KL-602 Syringe Pump – KellyMed
Europe style for Excelsior Syringe Pump - KL-602 Syringe Pump – KellyMed Detail:
FAQ
Q: Are you the manufacturer of this product?
A: Yes, since 1994.
Q: Do you have CE mark for this product?
A: Yes.
Q: Is you company ISO certified?
A: Yes.
Q: How many years warranty for this product?
A: Two years warranty.
Q: Date of delivery?
A: Normally within 1-5 working days after payment received.
Q: Is it capable of horizontal stacking of more than two pumps?
A: Yes, it is stackable up to 4 pumps or 6 pumps.
Specifications
Model | KL-602 |
Syringe Size | 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 0.1-9999 ml
<1000 ml in 0.1 ml increments ≥1000 ml in 1 ml increments |
Flow Rate | Syringe 10 ml: 0.1-400 ml/h
Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-900 ml/h Syringe 50/60 ml: 0.1-1300 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
Bolus Rate | 400 ml/h-1300 ml/h, adjustable |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy ≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus, system memory, key locker |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
Docking Station | Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 7 hours at 5 ml/h |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 hpa |
Size | 314*167*140 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅱ, type CF |
Product detail pictures:

Related Product Guide:
While in the past few years, our organization absorbed and digested innovative technologies both equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted for the advancement of Europe style for Excelsior Syringe Pump - KL-602 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Costa Rica, Senegal, Turin, Insisting over the high-quality generation line management and prospects guide provider, we've made our resolution to offer our shoppers using the initially stage purchasing and soon after provider working experience. Preserving the prevailing helpful relations with our prospects, we even now innovate our product lists the many time to meet up with the brand new wants and stick to the latest trend of this business in Ahmedabad. We're ready to facial area the difficulties and make the transform to grasp many of the possibilities in international trade.