head_banner

Factory Outlets Infusion And Syringe Pump - KL-702 Syringe Pump – KellyMed

Factory Outlets Infusion And Syringe Pump - KL-702 Syringe Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We always continually offer you the most conscientious purchaser services, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Intermittent Pneumatic Compression Therapy, Dual Channel Syringe Pump, Parenteral Nutrition Bag, "Making the Products of Large Quality" is definitely the everlasting purpose of our enterprise. We make unremitting endeavours to know the target of "We Will Always Hold in Pace along with the Time".
Factory Outlets Infusion And Syringe Pump - KL-702 Syringe Pump – KellyMed Detail:

FAQ

Q: Do you have CE mark for this product?

A: Yes.

Q: Dual channel syringe pump?

A: Yes, two channels which can be operated separately and simultaneously.

Q: Is the pump open system?

A: Yes, Universal syringe can be used with our Syringe Pump.

Q: It the pump available to have customized syringe?

A: Yes, we have two customized syringes.

Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?

A: Yes, it is memory function.

 

Specifications

Model KL-702
Syringe Size 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 0.1-10000 ml

100 ml in 0.1 ml increments

100 ml in 1 ml increments

Flow Rate Syringe 10 ml: 0.1-420 ml/h

Syringe 20 ml: 0.1-650 ml/h

Syringe 30 ml: 0.1-1000 ml/h

Syringe 50/60 ml: 0.1-1600 ml/h

100 ml/h in 0.1 ml/h increments

100 ml/h in 1 ml/h increments

Bolus Rate Syringe 10 ml: 200-420 ml/h

Syringe 20 ml: 300-650 ml/h

Syringe 30 ml: 500-1000 ml/h

Syringe 50/60 ml: 800-1600 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching, automatic syringe

identification, mute key, purge, bolus, anti-bolus, system memory,

history log, key locker, separate channel alarm, power saving mode

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life Power saving mode at 5 ml/h,

10 hours for single channel, 7 hours for double channel

Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 860-1060 hpa
Size 330*125*225 mm
Weight 4.5 kg
Safety Classification Class Ⅱ, type CF

Product detail pictures:

Factory Outlets Infusion And Syringe Pump - KL-702 Syringe Pump – KellyMed detail pictures


Related Product Guide:

The organization upholds the philosophy of "Be No.1 in good quality, be rooted on credit history and trustworthiness for growth", will keep on to provide previous and new customers from home and overseas whole-heatedly for Factory Outlets Infusion And Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: UAE, Israel, Denver, Our company has built stable business relationships with many well-known domestic companies as well as oversea customers. With the goal of providing high quality products to customers at low cots, we've been committed to improving its capacities in research, development, manufacturing and management. We have honored to receive recognition from our customers. Till now we have now passed ISO9001 in 2005 and ISO/TS16949 in 2008. Enterprises of "quality of survival, the credibility of development" for the purpose, sincerely welcome domestic and foreign businessmen to visit to discuss cooperation.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Ella from Toronto - 2017.12.09 14:01
    With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
    5 Stars By Juliet from Borussia Dortmund - 2017.06.16 18:23
    Write your message here and send it to us