head_banner

Free sample for T34 Ambulatory Syringe Pump - KL-605T Syringe Pump – KellyMed

Free sample for T34 Ambulatory Syringe Pump - KL-605T Syringe Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As a way to present you with ease and enlarge our enterprise, we also have inspectors in QC Workforce and assure you our greatest support and solution for Dual Syringe Pump, Vet Infusion Pump, Enfit Feeding Tube, Many years of work experience, we have realized the importance of providing good quality products and the best before-sales and after-sales services.
Free sample for T34 Ambulatory Syringe Pump - KL-605T Syringe Pump – KellyMed Detail:

FAQ

Q: Automatic recognition of syringe size and fixation

A: Yes.

Q: Syringe barrel clamp alarm?

A: Yes, it is Syringe Error alarm.

Q: Syringe plunger disengaged alarm?

A: Yes, it is Installation Error alarm.

Q: Automatic anti-bolus?

A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.

Q: Is it capable of horizontal stacking of more than two pumps?

A: Yes, it is stackable up to 4 pumps or 6 pumps.

 

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate Same as flow rate
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log, key locker

Drug Library Available
Occlusion Sensitivity High, medium, low
Docking Station Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord
History Log 50000 events
Wireless management Optional
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

Free sample for T34 Ambulatory Syringe Pump - KL-605T Syringe Pump – KellyMed detail pictures


Related Product Guide:

Our personnel are always inside the spirit of "continuous improvement and excellence", and together with the outstanding excellent goods, favorable price and good after-sales services, we try to gain every customer's trust for Free sample for T34 Ambulatory Syringe Pump - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Bogota, Cologne, Paraguay, Our staffs are adhering to the "Integrity-based and Interactive Development" spirit, and the tenet of "First-class Quality with Excellent Service". According to the needs of every customer, we provide customized & personalized services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
  • The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Michelle from Estonia - 2018.11.04 10:32
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Novia from Austria - 2018.06.09 12:42
    Write your message here and send it to us