head_banner

Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed

Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and excellent quality control throughout all stages of production enables us to guarantee total customer satisfaction for G Tube Feeding Pump, Syringe Pump Uk, Volumetric Pump, Looking to the future, a long way to go, constantly striving to become the all staff with full enthusiasm, one hundred times the confidence and put our company built a beautiful environment, advanced products, quality first-class modern enterprise and work hard!
Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed Detail:

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

10 ml: 0.1-300 ml/h

20 ml: 0.1-600 ml/h

30 ml: 0.1-800 ml/h

50/60 ml: 0.1-1200 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode 1. Easy mode

2. Flow rate

3. Time-based

4. Body weight

5. Plasma TCI

6. Effect TCI

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Power Supply, AC 110-230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed detail pictures


Related Product Guide:

To consistently enhance the management method by virtue of the rule of "sincerely, fantastic religion and top quality are the base of business development", we extensively absorb the essence of associated goods internationally, and constantly acquire new merchandise to satisfy the needs of shoppers for Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed , The product will supply to all over the world, such as: Bhutan, Iraq, kazan, Our products and solutions are sold to the Middle East, Southeast Asia, Africa, Europe, America and other regions, and are favorably appraised by clients. To benefit from our strong OEM/ODM capabilities and considerate services, be sure to contact us today. We will sincerely create and share success with all clients.
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Fay from Egypt - 2018.02.08 16:45
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Andrew from Zurich - 2018.06.12 16:22
    Write your message here and send it to us