High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for Mri Compatible Iv Pump, Lab Syringe Pump, Automated Syringe Pump, Adhering to the business philosophy of 'customer first, forge ahead', we sincerely welcome clients from at home and abroad to cooperate with us.
Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed Detail:

FAQ

Q: Automatic recognition of syringe size and fixation

A: Yes.

Q: Syringe barrel clamp alarm?

A: Yes, it is Syringe Error alarm.

Q: Syringe plunger disengaged alarm?

A: Yes, it is Installation Error alarm.

Q: Automatic anti-bolus?

A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.

Q: Is it capable of horizontal stacking of more than two pumps?

A: Yes, it is stackable up to 4 pumps or 6 pumps.

 

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate Same as flow rate
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log, key locker

Drug Library Available
Occlusion Sensitivity High, medium, low
Docking Station Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord
History Log 50000 events
Wireless management Optional
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed detail pictures


Related Product Guide:

Every single member from our large efficiency revenue team values customers' wants and company communication for Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Montreal, Naples, Doha, Our company's main products are widely used all over the world; 80% of our products exported to the United States, Japan, Europe and other markets. All stuff sincerely welcome guests come to visit our factory.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Debby from Poland - 2018.11.22 12:28
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Pag from Myanmar - 2018.09.21 11:44
    Write your message here and send it to us