Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed
Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed Detail:
FAQ
Q: Automatic recognition of syringe size and fixation?
A: Yes.
Q: Syringe barrel clamp alarm?
A: Yes, it is Syringe Error alarm.
Q: Syringe plunger disengaged alarm?
A: Yes, it is Installation Error alarm.
Q: Automatic anti-bolus?
A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.
Q: Is it capable of horizontal stacking of more than two pumps?
A: Yes, it is stackable up to 4 pumps or 6 pumps.
Specifications
Model | KL-605T |
Syringe Size | 5, 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 1-1000 ml (in 0.1, 1, 10 ml increments) |
Flow Rate | Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
Syringe 10 ml: 0.1-300 ml/h Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-800 ml/h Syringe 50/60 ml: 0.1-1200 ml/h |
Bolus Rate | Same as flow rate |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.01 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
Docking Station | Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord |
History Log | 50000 events |
Wireless management | Optional |
Power Supply, AC | 110/230 V, 50/60 Hz, 20 VA |
Battery | 14.8 V, rechargeable |
Battery Life | 8 hours at 5 ml/h |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 700-1060 hpa |
Size | 245*120*115 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅱ, type BF |
Product detail pictures:
Related Product Guide:
We purpose to understand high quality disfigurement with the output and supply the top service to domestic and overseas buyers wholeheartedly for Renewable Design for Medrena Syringe Pump - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Romania, Paris, Madras, We always hold on the company's principle "honest, professional, effective and innovation", and missions of: let all drivers enjoy their driving at night, let our employees can realize their value of life, and to be stronger and service more people. We are determined to become the integrator of our product market and one-stop service provider of our product market.