Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Beyond Syringe Pump, Set Infusion Pump, Kangaroo Enteral Feeding Pump, Sincere cooperation with you, altogether will create happy tomorrow!
Renewable Design for Medrena Syringe Pump - KL-702 Syringe Pump – KellyMed Detail:

FAQ

Q: Do you have CE mark for this product?

A: Yes.

Q: Dual channel syringe pump?

A: Yes, two channels which can be operated separately and simultaneously.

Q: Is the pump open system?

A: Yes, Universal syringe can be used with our Syringe Pump.

Q: It the pump available to have customized syringe?

A: Yes, we have two customized syringes.

Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?

A: Yes, it is memory function.

 

Specifications

Model KL-702
Syringe Size 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 0.1-10000 ml

<100 ml in 0.1 ml increments

≥100 ml in 1 ml increments

Flow Rate Syringe 10 ml: 0.1-420 ml/h

Syringe 20 ml: 0.1-650 ml/h

Syringe 30 ml: 0.1-1000 ml/h

Syringe 50/60 ml: 0.1-1600 ml/h

<100 ml/h in 0.1 ml/h increments

≥100 ml/h in 1 ml/h increments

Bolus Rate Syringe 10 ml: 200-420 ml/h

Syringe 20 ml: 300-650 ml/h

Syringe 30 ml: 500-1000 ml/h

Syringe 50/60 ml: 800-1600 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching, automatic syringe

identification, mute key, purge, bolus, anti-bolus, system memory,

history log, key locker, separate channel alarm, power saving mode

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life Power saving mode at 5 ml/h,

10 hours for single channel, 7 hours for double channel

Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 860-1060 hpa
Size 330*125*225 mm
Weight 4.5 kg
Safety Classification Class Ⅱ, type CF

Product detail pictures:

Renewable Design for Medrena Syringe Pump - KL-702 Syringe Pump – KellyMed detail pictures


Related Product Guide:

Our advancement depends on the superior gear ,superb talents and consistently strengthened technology forces for Renewable Design for Medrena Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Japan, Cyprus, Sevilla, We've been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying products and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.
  • This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Maureen from Bangladesh - 2017.12.09 14:01
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Claire from California - 2018.05.13 17:00
    Write your message here and send it to us