Specifications
| Model | KL-702 |
| Syringe Size | 10, 20, 30, 50/60 ml |
| Applicable Syringe | Compatible with syringe of any standard |
| VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
| Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
| Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
| Anti-Bolus | Automatic |
| Accuracy | ±2% (mechanical accuracy ≤1%) |
| Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
| KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
| Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
| Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
| Drug Library | Available |
| Occlusion Sensitivity | High, medium, low |
| History Log | 50000 events |
| Wireless Management | Optional |
| Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
| Battery | 9.6±1.6 V, rechargeable |
| Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
| Working Temperature | 5-40℃ |
| Relative Humidity | 20-90% |
| Atmospheric Pressure | 860-1060 hpa |
| Size | 330*125*225 mm |
| Weight | 4.5 kg |
| Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
To continually enhance the management technique by virtue of your rule of "sincerely, great faith and high-quality are the base of company development", we widely absorb the essence of similar merchandise internationally, and continuously build new merchandise to meet the demands of customers for Renewable Design for Medrena Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Russia, Sri Lanka, Chile, We've got constructed strong and long co-operation relationship with an enormous quantity of companies within this business in Kenya and overseas. Immediate and professional after-sale service supplied by our consultant group has happy our buyers. Thorough Info and parameters from the merchandise will probably be sent for you for any thorough acknowledge. Free samples may be delivered and company check out to our corporation. n Kenya for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.