head_banner

Short Lead Time for Mri Iv Pump - ZNB-XAII Infusion Pump – KellyMed

Short Lead Time for Mri Iv Pump - ZNB-XAII Infusion Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our staff are usually in the spirit of "continuous improvement and excellence", and while using the top-quality high-quality items, favorable value and superior after-sales services, we try to acquire each and every customer's belief for Electronic Infusion Pump, Nutrition Feeding Set, Peg Tube Enteral Feeding, Looking to the future, a long way to go, constantly striving to become the all staff with full enthusiasm, one hundred times the confidence and put our company built a beautiful environment, advanced products, quality first-class modern enterprise and work hard!
Short Lead Time for Mri Iv Pump - ZNB-XAII Infusion Pump – KellyMed Detail:

FAQ

Q: Is the pump open system?

A: Yes, Universal IV set can be used with our Infusion Pump after calibration.

Q: Does the pump compatible with Micro IV Set (1 ml=60 drops)?

A: Yes, all of our pumps are compatible with IV Set of 15/20/60 dorps.

Q: Is it a peristaltic pumping mechanism?

A: Yes, curvilinear peristaltic.

Q: What is the difference between PURGE and BOLUS function?

A: Purge used to remove air in line before infusion. Bolus can be administered for infusion therapy during infusion. Both purge and bolus rate are programmable.

 

Specifications

Model ZNB-XAII
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 0.1 ml/h increments)

Purge when pump stops, bolus when pump starts

Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-20000 ml (in 0.1 ml increments)
Infusion Mode ml/h, drop/min, time-based, body weight, nutrition
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby

Additional Features Real-time infused volume, automatic power switching, mute key,

purge, bolus, system memory, history log, key locker, drug library,

rotary knob, change flow rate without stopping the pump

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Air-in-line Detection Ultrasonic detector
Wireless management Optional
Drop Sensor Optional
Vehicle Power (Ambulance) 12±1.2 V
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 25 ml/h
Working Temperature 10-30℃
Relative Humidity 30-75%
Atmospheric Pressure 860-1060 hpa
Size 130*145*228 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF

Product detail pictures:

Short Lead Time for Mri Iv Pump - ZNB-XAII Infusion Pump – KellyMed detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization to the long-term to build together with shoppers for mutual reciprocity and mutual advantage for Short Lead Time for Mri Iv Pump - ZNB-XAII Infusion Pump – KellyMed , The product will supply to all over the world, such as: Macedonia, Rwanda, United Arab Emirates, High output volume, top quality, timely delivery and your satisfaction are guaranteed. We welcome all inquiries and comments. We also offer agency service---that act as the agent in china for our customers. If you are interested in any of our products or have an OEM order to fulfill, please feel free to contact us now. Working with us will save you money and time.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Zoe from Honduras - 2017.03.08 14:45
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Gill from Manila - 2017.08.18 18:38
    Write your message here and send it to us