Wholesale Syringe Pump Use - KL-702 Syringe Pump – KellyMed
Wholesale Syringe Pump Use - KL-702 Syringe Pump – KellyMed Detail:
FAQ
Q: Do you have CE mark for this product?
A: Yes.
Q: Dual channel syringe pump?
A: Yes, two channels which can be operated separately and simultaneously.
Q: Is the pump open system?
A: Yes, Universal syringe can be used with our Syringe Pump.
Q: It the pump available to have customized syringe?
A: Yes, we have two customized syringes.
Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?
A: Yes, it is memory function.
Specifications
| Model | KL-702 |
| Syringe Size | 10, 20, 30, 50/60 ml |
| Applicable Syringe | Compatible with syringe of any standard |
| VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
| Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
| Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
| Anti-Bolus | Automatic |
| Accuracy | ±2% (mechanical accuracy ≤1%) |
| Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
| KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
| Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
| Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
| Drug Library | Available |
| Occlusion Sensitivity | High, medium, low |
| History Log | 50000 events |
| Wireless Management | Optional |
| Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
| Battery | 9.6±1.6 V, rechargeable |
| Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
| Working Temperature | 5-40℃ |
| Relative Humidity | 20-90% |
| Atmospheric Pressure | 860-1060 hpa |
| Size | 330*125*225 mm |
| Weight | 4.5 kg |
| Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for Wholesale Syringe Pump Use - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Liberia, Ghana, Lithuania, We rely on high-quality materials, perfect design, excellent customer service and the competitive price to win the trust of many customers at home and abroad. 95%products are exported to overseas markets.