2021 High quality Intermittent Pneumatic Compression Pump - KL-605T TCI Pump – KellyMed
2021 High quality Intermittent Pneumatic Compression Pump - KL-605T TCI Pump – KellyMed Detail:
Specifications
Model | KL-605T |
Syringe Size | 5, 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 1-1000 ml (in 0.1, 1, 10 ml increments) |
Flow Rate | Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
Syringe 10 ml: 0.1-300 ml/h Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-800 ml/h Syringe 50/60 ml: 0.1-1200 ml/h |
Bolus Rate | 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
10 ml: 0.1-300 ml/h 20 ml: 0.1-600 ml/h 30 ml: 0.1-800 ml/h 50/60 ml: 0.1-1200 ml/h |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy≤1%) |
Infusion Mode | 1. Easy mode
2. Flow rate 3. Time-based 4. Body weight 5. Plasma TCI 6. Effect TCI |
KVO Rate | 0.1-1 ml/h (in 0.01 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus, system memory, history log |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
History Log | 50000 events |
Power Supply, AC | 110-230 V, 50/60 Hz, 20 VA |
Battery | 14.8 V, rechargeable |
Battery Life | 8 hours at 5 ml/h |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 700-1060 hpa |
Size | 245*120*115 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅱ, type BF |
Product detail pictures:

Related Product Guide:
We have our own product sales staff, style crew, technical group, QC staff and package staff. We now have strict high quality management procedures for each approach. Also, all of our workers are experienced in printing subject for 2021 High quality Intermittent Pneumatic Compression Pump - KL-605T TCI Pump – KellyMed , The product will supply to all over the world, such as: Sudan, Australia, Irish, Besides there are also experienced production and management , advanced production equipment to assure our quality and delivery time , our company pursues the principle of good faith, high-quality and high-efficiency. We guarantee that our company will try our best to reduce customer purchase cost, shorten the period of purchase, stable solutions quality, increase customers' satisfaction and achieve win-win situation .