Warmer for blood transfusion, infusion, enteral nutrition, parenteral nutrition
Our primary intention will be to provide our clientele a serious and responsible small business relationship, giving personalized attention to all of them for Warmer for blood transfusion, infusion, enteral nutrition, parenteral nutrition, The crew of our corporation together with the use of cutting-edge technologies delivers impeccable high quality merchandise supremely adored and appreciated by our shoppers all over the world. Our primary intention will be to provide our clientele a serious... -
China New Product Targeted Control Pump KL-605T TCI
Features
1. Work mode:
constant infusion, intermittent infusion, TCI (Target Control Infusion).
2. Multiply infusion mode:
easy mode, flow rate, time, body weight, plasma TCI, effect TCI
3. TCI calculate mode:
maximum mode, increment mode, constant mode.
4. Compatible with syringe of any standard.
5. Adjustable bolus rate 0.1-1200 ml/h in 0.01, 0.1, 1, 10 ml/h increment.
6. Adjustable KVO rate 0.1-1 ml/h in 0.01 ml/h increments.
7. Automatic anti-bolus.
8. Drug library.
9. History log of 50,000 events.
10. Stackable for multiple channels.
-
Volumetric Pump
1. Ulltrasonic air-in-line detection.
2. Wide range of flow rate & VTBI.
3. Nurse call connectivity.
4. Vehicle power (Ambulance) connectivity.
5. Drug library with more than 60 drugs.
6. History log of 50000 events.
7. Twin CPU’s to make infusion process safer.
8. Comprehensive visible and audible alarms.
9. Key information and self explaining user instructions on display.
10. More infusion modes: flow rate, drop/min, time, body weight, nutrition
11. Excellent Prize of “2010 China Red Star Design Award”
-
Syringe Pump KL-6061N compatible with KL-6061N
Features :
1.Large LCD display
2. Wide range of flow rate from 0.01~9999.99 ml/h ;(in 0.01 ml increments)
3.Automatic KVO with On/Off Function
4.Dynamic pressure monitoring.
5. 8 working modes , 12 levels occlusion sensitivity.
6. workable with docking station .
7.Automatic multi-channel relay.
8. Multiple data transmission
-
Dual channel syringe pump from KellyMed
Features:
1. Dual channel, separate audio-visual alarm.
2. Infusion mode: flow rate, time-based, body weight
3. Applicable syringe size: 10, 20, 30, 50/60 ml.
4. Automatic syringe size detection.
5. Automatic anti-bolus.
6. Automatic calibration.
7. Drug library with more than 60 drugs.
8. Wireless management: central monitoring by Infusion Management System
9. Night mode for power saving.
-
Volumetric Pump
1. Ulltrasonic air-in-line detection.
2. Wide range of flow rate & VTBI.
3. Nurse call connectivity.
4. Vehicle power (Ambulance) connectivity.
5. Drug library with more than 60 drugs.
6. History log of 50000 events.
7. Twin CPU’s to make infusion process safer.
8. Comprehensive visible and audible alarms.
9. Key information and self explaining user instructions on display.
10. More infusion modes: flow rate, drop/min, time, body weight, nutrition
11. Excellent Prize of “2010 China Red Star Design Award”
-
Infusion pump for both adult and neonatal
Features:
1. Built-in thermostat: 30-45℃ adjustable.
This mechanism warms IV tubing to increase infusion accuracy.
This is a unique feature compare to other Infusion Pumps.
2. Advanced mechanics for high infusion accuracy and consistency.
3. Applicable for adult, Paediatrics and NICU (Neonatal).
4. Anti-free-flow function to make infusion safer.
5. Real-time display of infused volume / bolus rate / bolus volume / KVO rate.
6, Large LCD display. Visible on-screen 9 alarms.
7. Change flow rate without stopping the pump.
8. Twin CPU’s to make infusion process safer.
9. Up to 5 hours battery backup, battery status indication.
10. Easy to use operation philosophy.
11. Recommended model by worldwide medical staff.
-
KellyMed Dual channel syringe pump KL-702 MDR CE certificate
Features:
1. Dual channel, separate audio-visual alarm.
2. Infusion mode: flow rate, time-based, body weight
3. Applicable syringe size: 10, 20, 30, 50/60 ml.
4. Automatic syringe size detection.
5. Automatic anti-bolus.
6. Automatic calibration.
7. Drug library with more than 60 drugs.
8. Wireless management: central monitoring by Infusion Management System
9. Night mode for power saving.
-
Feeding Pump KL-5021A
1. Palm size, portable.
2. Detachable charging base.
3. Up to 8 hours battery backup, battery status indication.
4. Withdraw and cleaning at adjustable rate.
5. Infusion warmer at adjustable temperature.
6. Compatible with vehicle power for ambulance.
7. Real-time display of VTBI / flow rate / infused volume.
8. DPS, the dynamic pressure system, detection of pressure variations in line.
9. On-site checking of history log up to 50000 events.
10. Wireless management: central monitoring by Infusion Management System.
-
KellyMed Profeeeional Syringe Pump Manufacturer Two Way Syringe Pump KL-702
Features:
1. Dual channel, separate audio-visual alarm.
2. Infusion mode: flow rate, time-based, body weight
3. Applicable syringe size: 10, 20, 30, 50/60 ml.
4. Automatic syringe size detection.
5. Automatic anti-bolus.
6. Automatic calibration.
7. Drug library with more than 60 drugs.
8. Wireless management: central monitoring by Infusion Management System
9. Night mode for power saving.
-
KellyMed KL-8071A CE/FDA Certified Advanced Curvilinear Peristaltic Infusion Pump – Real-Time Monitoring & Wireless Management for Precision Fluid Delivery in Veterinary, Ambulance & Hospital Settings
Features:
1.Compact, portable
2.Can be used on ambulance
3.Work principle: curvilinear peristalitic ,this mechanism warms IV tubing to increase infusion accuracy.
4. Anti-free-flow function to make infusion safer.
5. Real-time display of infused volume / bolus rate / bolus volume / KVO rate.
6. Visible on-screen 9 alarms.
7. Change flow rate without stopping the pump.
8.Lithium battery, wide voltage from 110-240V
-
KL-602 Syringe Pump: Advanced Precision Infusion System with Automatic Syringe Size Detection, Anti-Bolus Function, and Wireless Management Capability. Designed for Medical and Laboratory Use with ±2% Accuracy
Features:
1. Applicable syringe size: 10, 20, 30, 50/60 ml.
2. Automatic syringe size detection.
3. Automatic anti-bolus.
4. Automatic calibration.
5. Drug library with more than 60 drugs.
6. Audio-visual alarm insures further safety.
7. Wireless management by Infusion Management System.
8. Stackable up to 4 Syringe Pumps (4-in-1 Docking Station) or 6 Syringe Pumps (6-in-1 Docking Station) with single power cord.
9. Easy to use operation philosophy
10. Recommended model by worldwide medical staff.