To fulfill the customers' over-expected satisfaction , we have now our strong crew to provide our greatest general assistance which incorporates promoting, gross sales, planning, creation, top quality controlling, packing, warehousing and logistics for Medima Infusion Pump, Types Of Enteral Feeding Tubes, Syringe Pump Online, We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.
New Fashion Design for Different Types Of Iv Pumps - ZNB-XK Infusion Pump – KellyMed Detail:

FAQ

Q: Do you have infusion mode of drop/min?

A: Yes.

Q: Does the pump have self-test facility?

A: Yes, it is automatically started when you switch on the pump.

Q: Does the pump have audible and visible alarms?

A: Yes, all the alarms are audible and visible.

Q: Does the pump save last bolus rate even when the AC power is switched OFF?

A: Yes, it is memory function.

Q: Does the pump have front panel lock-out mechanism to protect against incorrect operations?

A: Yes, it is key locker.

 

Specifications

Model ZNB-XK
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1300 ml/h (in 0.1 ml/h increments)
Purge, Bolus Purge when pump stops, bolus when pump starts, rate at 1100 ml/h
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-9999 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby

Additional Features Real-time infused volume, automatic power switching,

mute key, purge, bolus, system memory, key locker, nurse call

Occlusion Sensitivity 5 levels
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Drop Sensor Optional
Nurse Call Available
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 6 hours at 30 ml/h
Working Temperature 10-40℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Size 233*146*269 mm
Weight 3 kg
Safety Classification Class Ⅰ, type CF

Product detail pictures:

New Fashion Design for Different Types Of Iv Pumps - ZNB-XK Infusion Pump – KellyMed detail pictures


Related Product Guide:

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for New Fashion Design for Different Types Of Iv Pumps - ZNB-XK Infusion Pump – KellyMed , The product will supply to all over the world, such as: Thailand, Guinea, St. Petersburg, We only supply quality items and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom merchandise etc that can according to customer's requirement.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Darlene from Orlando - 2017.03.28 12:22
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Lydia from Cambodia - 2018.12.11 14:13
    Write your message here and send it to us