To continuously increase the administration process by virtue of the rule of "sincerely, good religion and excellent are the base of company development", we commonly absorb the essence of linked goods internationally, and continually build new solutions to fulfill the requires of shoppers for Alaris Iv Pump, Electronic Infusion Pump, Curlin 6000 Infusion Pump, Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
Short Lead Time for Tci Syringe Pump - KL-605T Syringe Pump – KellyMed Detail:

FAQ

Q: Automatic recognition of syringe size and fixation

A: Yes.

Q: Syringe barrel clamp alarm?

A: Yes, it is Syringe Error alarm.

Q: Syringe plunger disengaged alarm?

A: Yes, it is Installation Error alarm.

Q: Automatic anti-bolus?

A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.

Q: Is it capable of horizontal stacking of more than two pumps?

A: Yes, it is stackable up to 4 pumps or 6 pumps.

 

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate Same as flow rate
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log, key locker

Drug Library Available
Occlusion Sensitivity High, medium, low
Docking Station Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord
History Log 50000 events
Wireless management Optional
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

Short Lead Time for Tci Syringe Pump - KL-605T Syringe Pump – KellyMed detail pictures


Related Product Guide:

With our rich experience and considerate services, we have been recognized as a reliable supplier for many international buyers for Short Lead Time for Tci Syringe Pump - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Argentina, Hanover, Philadelphia, We warmly welcome domestic and overseas customers to visit our company and have business talk. Our company always insists on the principle of "good quality, reasonable price, the first-class service". We have been willing to build long-term, friendly and mutually beneficial cooperation with you.
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By John biddlestone from Armenia - 2018.09.08 17:09
    In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Renata from Anguilla - 2017.09.16 13:44
    Write your message here and send it to us