KellyMed Syringe Pump KL-6061N working station
KellyMed Syringe Pump KL-6061N working station,
,



Syringe Pump KL-6061N
Specifications
| Syringe Size | 5,10, 20, 30, 50/60 ml | 
| Applicable Syringe | Compatible with syringe of any standard | 
| Flow Rate | Syringe 5 ml: 0.1-100 ml/hSyringe 10 ml: 0.1-300 ml/hSyringe 20 ml: 0.1-600 ml/hSyringe 30 ml: 0.1-800 ml/hSyringe 50/60 ml: 0.1-1500 ml/h 0.1-99.99 mL/h, in 0.01 ml/h increments 100-999.9 ml/h in 0.1 ml/h increments 1000-1500 ml/h in 1 ml/h increments | 
| Flow Rate Accuracy | ±2% | 
| VTBI | 0.10mL~99999.99mL (Minimum in 0.01 ml/h increments) | 
| Accuracy | ±2% | 
| Time | 00:00:01~99:59:59(h:m:s) (Minimum in 1s increments) | 
| Flow Rate ( Body weight ) | 0.01~9999.99 ml/h ;(in 0.01 ml increments)unit: ng/kg/min、ng/kg/h、ug/kg/min、ug/kg/h、mg/kg/min、mg/kg/h、IU/kg/min、IU/kg/h、EU/kg/min、EU/kg/h | 
| Bolus Rate | Syringe 5 ml: 50mL/h-100.0 mL/hSyringe 10 ml: 50mL/h-300.0 mL/hSyringe 20 ml: 50mL/h-600.0 mL/hSyringe 30 ml: 50mL/h-800.0 mL/hSyringe 50/60 ml: 50mL/h-1500.0 mL/h 50-99.99 mL/h, in 0.01 ml/h increments 100-999.9 ml/h in 0.1 ml/h increments 1000-1500 ml/h in 1 ml/h increments Accuray: ±2% | 
| Bolus Volume | Syringe 5 ml: 0.1mL-5.0 mLSyringe 10 ml: 0.1mL-10.0 mLSyringe 20 ml: 0.1mL-20.0 mLSyringe 30 ml: 0.1mL-30.0 mLSyringe 50/60 ml: 0.1mL-50.0 /60.0mL Accuracy: ±2% or ±0.2mL | 
| Bolus , Purge | Syringe 5mL :50mL/h -100.0 mL/hSyringe 10mL:50mL/h -300.0 mL/hSyringe 20mL:50 mL/h -600.0 mL/hSyringe 30mL:50 mL/h -800.0 mL/hSyringe 50mL:50 mL/h -1500.0 mL/h (Minimum in 1mL/h increments) Accuracy: ±2% | 
| Occlusion Sensitivity | 20kPa-130kPa, adjustable (in 10 kPa increments)Accuracy: ±15 kPa or±15% | 
| KVO Rate | 1).Automatic KVO On/Off Function2).Automatic KVO is turned off : KVO Rate : 0.1~10.0 mL/h adjustable,(Minimum in 0.1mL/h increments).When flow rate>KVO rate , it runs in KVO rate.When flow rate <KVO rate , it alarms and runs in flow rate.3) Automatic KVO is turned on:it adjusts the flow rate automatically. When flow rate<10mL/h, KVO rate =1mL/h When flow rate >10 mL/h, KVO=3 mL/h. Accuracy: ±2% | 
| Basic function | Dynamic pressure monitoring, Anti-Bolus, Key Locker, Standby, Historical memory, Drug library. | 
| Alarms | Occlusion, syringe drop off, door open, near end , end program, low battery, end battery, motor malfunction, system malfunction, standby alarm, syringe installation error | 
| Infusion Mode | Rate mode, Time mode, Body weight, Sequence Mode、Dose Mode、Ramp Up/Down Mode、Micro-Infu Mode | 
| Additional Features | Self-checking, System Memory, Wireless (optional), Cascade, Battery Missing Prompt, AC Power Off Prompt. | 
| Air-in-line Detection | Ultrasonic detector | 
| Power Supply, AC | AC100V~240V 50/60Hz, 35 VA | 
| Battery | 14.4 V, 2200mAh ,Lithium, rechargeable | 
| Weight of Battery | 210g | 
| Battery Life | 10 hours at 5 ml/h | 
| Working Temperature | 5℃~40℃ | 
| Relative Humidity | 15%~80% | 
| Atmospheric Pressure | 86KPa~106KPa | 
| Size | 290×84×175mm | 
| Weight | <2.5 kg | 
| Safety Classification | Class ⅠI, type CF. IPX3 | 






FAQ:
Q:what’s the MOQ for this model ?
A: 1 unit.
Q: Is the OEM acceptable ? and what is the MOQ for OEM ?
A: Yes , We can do OEM based on 30 units .
Q: Are you the manufacture of this product.
A: Yes, since 1994
Q: Do you have CE and ISO certificates?
A: Yes . all our products are CE and ISO certified
Q: What is the warranty ?
A: We give two years warranty.
Q: Is this model workable with Docking station?
A: Yes

 Features :
Features :
➢ Compact in design, light in weight and small in size.
➢ simple and easy to use
➢ Low running noise.
➢ 9 working modes
➢ Built-in 3 brands of syringe data, convenient for choosing syringes.
➢ User can define 2 syringes data into the pump.
➢ Anti-Bolus function
➢ Audio-visual alarms for added safety
➢ Display critical clinical dates simultaneously
➢ The pump enters KVO (KEEP VEIN OPEN) mode automatically once injection of VTBI is finished.
 
				






 
			 
			 
			 
			