Volumetric Pump
Volumetric Pump,
,
FAQ
Q: Is the pump open system?
A: Yes, Universal IV set can be used with our Infusion Pump after calibration.
Q: Does the pump compatible with Micro IV Set (1 ml=60 drops)?
A: Yes, all of our pumps are compatible with IV Set of 15/20/60 dorps.
Q: Is it a peristaltic pumping mechanism?
A: Yes, curvilinear peristaltic.
Q: What is the difference between PURGE and BOLUS function?
A: Purge used to remove air in line before infusion. Bolus can be administered for infusion therapy during infusion. Both purge and bolus rate are programmable.
Specifications
| Model | ZNB-XAII |
| Pumping Mechanism | Curvilinear peristaltic |
| IV Set | Compatible with IV sets of any standard |
| Flow Rate | 1-1500 ml/h (in 0.1 ml/h increments) |
| Purge, Bolus | 100-1500 ml/h (in 0.1 ml/h increments)
Purge when pump stops, bolus when pump starts |
| Accuracy | ±3% |
| *Inbuilt Thermostat | 30-45℃, adjustable |
| VTBI | 1-20000 ml (in 0.1 ml increments) |
| Infusion Mode | ml/h, drop/min, time-based, body weight, nutrition |
| KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
| Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby |
| Additional Features | Real-time infused volume, automatic power switching, mute key,
purge, bolus, system memory, history log, key locker, drug library, rotary knob, change flow rate without stopping the pump |
| Drug Library | Available |
| Occlusion Sensitivity | High, medium, low |
| History Log | 50000 events |
| Air-in-line Detection | Ultrasonic detector |
| Wireless management | Optional |
| Drop Sensor | Optional |
| Vehicle Power (Ambulance) | 12±1.2 V |
| Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
| Battery | 9.6±1.6 V, rechargeable |
| Battery Life | 5 hours at 25 ml/h |
| Working Temperature | 10-30℃ |
| Relative Humidity | 30-75% |
| Atmospheric Pressure | 860-1060 hpa |
| Size | 130*145*228 mm |
| Weight | 2.5 kg |
| Safety Classification | Class Ⅰ, type CF |





Features:
1. Inbuilt thermostat: 30-45℃ adjustable.
This mechanism warms IV tubing to increase infusion accuracy.
This is a unique feature compare to other Infusion Pumps.
2. Wide range of flow rate & VTBI.
3. Advanced mechanics for high infusion accuracy and consistency.
4. Anti-free-flow function to make infusion safer.
5. Drug library with more than 60 drugs.
6. Compatible with vehicle power for ambulance.
7. History log of 50,000 events.
8. Twin CPU’s to make infusion process safer.
9. Change flow rate without stopping the pump.
Model ZNB-XAII
Pumping Mechanism Linear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 0.1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 0.1 ml/h increments)
Purge when pump stops, bolus when pump starts
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-20000 ml (in 0.1 ml increments)
Infusion Mode ml/h, drop/min, time-based, body weight, nutrition
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby
Additional Features Real-time infused volume, automatic power switching, mute key,
purge, bolus, system memory, history log, key locker, drug library,
rotary knob, change flow rate without stopping the pump
Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Air-in-line Detection Ultrasonic detector
Wireless management Optional
Drop Sensor Optional
Vehicle Power (Ambulance) 12±1.2 V
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 25 ml/h
Working Temperature 10-30℃
Relative Humidity 30-75%
Atmospheric Pressure 860-1060 hpa
Size 130*145*228 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF